Close

HT45S40U

Print this page
Description
  • Brand APEM
  • Product CodeHT45S40U
  • Stock StatusPre-order
  • Stock0
APEM HT Series 3 Axis 2 Button Hall Effect Joystick

The HT Series joystick is a long life cycle,
Hall effect controller providing reliable multi-axes finger positioning control.
Available in single, dual, and triple axes configurations,
HT Series joysticks are ideal for harsh environments, finger operated applications requiring increased durability and reliability.
Widely used applications include on-road enclosed cabin vehicles, unmanned vehicles and military robotics.
504.00 €
Piece
Piece Unit price Total
Property Name Property Value
SERIES HT
HANDLE 2 Pushbuttons (3 Axis)
LIMITER PLATE Square
MOUNTING Rear Mount
OUTPUT OPTIONS 0V to 5V (Rail to Rail)
We'll Call You


Thank you,
We will contact you as soon as possible

Send
  • MECHANICAL (FOR X, Y AXES)
    Break Out Force – 1.8N (0.4lbf)
    Operating Force – 3.5N (0.75lbf)
    Maximum Applied Force – 450N (100lbf)
    Mechanical Angle of Movement – 40˚
    Expected Life – 10 million cycles
    Material – Glass filled nylon
    Lever Action – Spring centering

    MECHANICAL (FOR Z AXIS)
    Break Out Torque – 0.09N·m (0.80lbf·in)
    Operating Torque – 0.121N·m (1.07lbf·in)
    Maximum Allowable Torque – 0.150N·m (1.33lbf·in)
    Hand Mechanical Angle – 60°
    Handle Action – Spring centering
    Expected Life – 10 million cycles

    ENVIRONMENTAL
    Operating Temperature – -25ºC to 70ºC (-13ºF to 158ºF)
    Storage Temperature – -40ºC to 70ºC (-40ºF to 158ºF)
    Sealing (IP) – IP65 to IP68*
    EMC Immunity Level (V/M) – IEC 61000-4-3: 2006
    EMC Emissions Level – IEC 61000-4-8: 1993/A1: 2000
    ESD – IEC 61000-4-2: 2008
    Vibration Crash (non operational) – IAW MIL-STD-810F Method 516.5 Procedure V, Table
    516.5-8 SRS (75G)
    Vibration Shock (non operational) – IAW MIL-STD-810F, Method 516.5, Procedure 1, 40G
    peak sine wave pulse with 11ms duration
    Vibration Shock (operational) – IAW MIL-STD-810F, Method 516.5, Procedure, 20G peak
    half sine wave pulse with 11ms duration

    ELECTRICAL
    Sensor – Hall effect
    Resolution – Infinite
    Supply Voltage Operating – 5.00VDC
    Reverse Polarity Max – –14.5VDC
    Overvoltage Max – 18VDC
    Output Voltage – See options
    Output Impedance – 6Ω
    Current Consumption Max – 10mA per axis
    Return to Center Voltage (No Load) – ±200mV
    Output Ramp – See options
    CANbus OUTPUT VERSION
    Supply Voltage Range – 6V to 40V
    CANbus Version – J1939

    NOTES:
    - All values are nominal
    - Exact specifications may be subject to configuration.
    Contact Technical Support for the performance of your specific configuration.